See gounding method shown below (Figure 4.). Options . The end user will have to install two separate push buttons to the appropriate terminals on the Remote Stop / Equalize circuit board (see schematic 4120-66-68650-50) and locate them to a. convenient location for use. The GNB SCRFLX battery chargers are convection cooled, solid state, micro-processor controlled SCR regulated chargers designed to make battery charging simple. 7.0 APPLICATION The charger will automatically charge a battery per the Ah rating set at the factory. Industrial battery chargers dec200 series (20 pages), Scr series chargers with single phase input (68 pages), Scr 100 series industrial battery charger (39 pages), Dedicated fast charger for industrial batteries (19 pages), Manual will be automatically added to "My Manuals", Battery Charger GNB Industrial Battery Charger Installation And Operation Manual, Battery Charger GNB SCR SERIES Installation & Operating Instructions Manual, Battery Charger GNB SCR100-06-260S1Z Installation & Operating Instructions Manual, Battery Charger GNB EHF Series Operating Instructions And Safety Manual, Battery Charger GNB FURY X-3 Installation And Operating Instruction Manual, Battery Charger GNB Tubular LMX Installation And Operating Instructions. To ensure good continuity keep the contact area clean. The inspection and maintenance of the charger is very important in the daily use of the electric forklift. If DC cable lengths are adjusted please contact you local GNB service representative. Ensure that battery and charger are matched. During year four (4) of the warranty, GNB will only cover parts, no labor or travel will be provided by GNB. WARNING: TO REDUCE THE RISK OF FIRE, INSTALL BATTERY CHARGER ON A FLOOR OF NON-COMBUSTIBLE MATERIAL SUCH AS. We will report back on the show itself next week, but the most significant news for the European equipment sector has probably been overlooked in the lead-up to the show. WARNING: DO NOT OPERATE THE UNIT WITHOUT PROPER GROUNDING. This change should be done by a qualified electrical contractor. Exide Technologies SCR100 User Manual - ManualMachine.com United Kingdom. When changing the taps on the input side between 1) 120, 208, 240 VAC or 2) 208, 240, 480 VAC (single phase input), be sure to change the wires and/or jumpers according to Figure 1 (page 4). Do not operate this unit if it has received a sharp blow, been dropped or otherwise damaged. They are designed to charge flooded lead-acid batteries only. The charger profile is set at the factory for a charger DC cable length of 9ft and a battery DC cable length of 25in. This change should be done by a qualified electrical contractor. Exide Depth Charger codes C=01 & E=05 I have a battery charger that is displaying the above codes. | , Standard drawings, professional and technical teams, Win the witness of thousands of enterprises, How to deep discharge inspection of forklift battery, The main point of adding water to the forklift battery. IMPORTANT OPERATING AND SAFETY INSTRUCTIONS, 9.1 SCR100 Charger Functional Description, APPENDIX A: SCR100 BATTERY CHARGERS LIST OF DISPLAY INDICATIONS, APPENDIX B: ELECTRICAL SCHEMATIC DRAWINGS, SCR100 SERIES INDUSTRIAL BATTERY CHARGERS, 1.0 IMPORTANT OPERATING AND SAFETY INSTRUCTIONS. Electric forklift battery charger troubleshooting points 100% 8 Hour Charger Rated to fully recharge a 100% discharged battery within 8 hours. Follow Figure 1 (page 4) for single phase input or Figure 2 and Figure 3 (pages 5-6) for three phase input transformers. The following options are available: Only the AC input wire configuration for multi-input chargers can be changed. Verify AC voltage per nameplate of the charger and electricians tag. member exclusive content. FOR SUPPLY CONNECTIONS, GROUND CHARGER PROPERLY USING GROUNDING STUD (GND) PROVIDED. If the battery is unplugged during charging, the charger will indicate OFF/FCA. D3E2-24-850B Exide Depth Charger showing codes C=04 & E=05 with connected battery and disconnected too.. The following notes are for the guidance of the, The charger must be i solated from the input supply and t he, battery, before any of the panels are removed. We will report back on the show itself next week, but the most significant news for the European equipment sector has probably been overlooked in the lead-up to the show. | Contact Us GNB NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR GNB ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OR USE OF THE PRODUCT, AND THERE ARE NO ORAL AGREEMENTS OR WARRANTIES COLLATERAL TO OR AFFECTING THIS WRITTEN WARRANTY. All SCRFLX battery chargers can come with a factory installed fused JIC switch assembly option for extra protection of the operator. PACIFIC CHLORIDE GNB Industrial Power Motive Power GNB Industrial Power Motive Power Exide Technologies Chloride Motive Power 829 Parkview Boulevard Lombard, IL 60148-3249 U.S.A. Tel: 877.GNB.INFO Fax: 630.691.7869 8301 Keele Street Maple, Ontario Canada L6A 1T2 Tel: 905.669.9326 Fax: 905.669.7688 P.O. Have the charger examined by a GNB service representative or local qualified service facility. STONE, BRICK, CONCRETE OR METAL. 4.1GNBs liability is limited to the repair of the defect or, at GNBs option, the replacement of the defective parts. permanently connected to the mains supply. The charger should be permanently connected to the mains supply. 3. h)This charger is factory set to charge flooded lead-acid batteries only. All SCR100 battery chargers can come with a factory installed fused JIC switch assembly option for extra protection of the operator. They are designed to charge flooded lead-acid batteries only. The DC charging cable has a commonly used battery plug or receptacle. endstream endobj startxref Is the stream module damaged? hmo8r#x)tr^C Step 1: Check if the mains power supply has electricity and if the battery is under voltage 4. The Remote Stop / Equalize option is available for Z model chargers B and C cabinets, 6 36 cells only. a)Before using the battery charger, read all the instructions in addition to the CAUTION, WARNING, and DANGER markings on the charger, battery and all the associated equipment. TABLE OF CONTENTS TITLE PAGE 1.0 IMPORTANT OPERATING AND SAFETY INSTRUCTIONS 2 2.0 INTRODUCTION 3 3.0 RECEIVING CHARGER 3 4.0 LOCATION AND INSTALLATION OF CHARGER 3 4.1 Stacking 3 5.0 AC ELECTRICAL SUPPLY 3 5.1 AC Fuse Mounting 3 5.2 Input Voltage Change 3 5.3 AC Voltage Connections 7 5.4 Ground connection 7 6.0 DC OUTPUT 7 7.0 APPLICATION 8 7.1 Display and Fault Codes 8 7.2 Options 8 TABLE 2 - SINGLE PHASE RATINGS 9 TABLE 3 - THREE PHASE RATINGS 11 8. Having trouble using the Discussion Forums? LIST OF DISPLAY INDICATIONS. 5 Jan 2011 09:59, Posted The diode file of the multimeter can also be used to determine the break. TABLE 3 THREE PHASE TECHNICAL DATA AC AMPS @ AC VOLTS STANDARD MODEL DC 60Hz SCRFLX-XX-XXXX-T1Z AMPS SCRFLX-18-1050T1Z SCRFLX-18-1200T1Z SCRFLX-18-1450T1Z SCRFLX-18-1700T1Z SCRFLX-24-475T1Z SCRFLX-24-600T1Z SCRFLX-24-1050T1Z SCRFLX-24-1200T1Z SCRFLX-24-1450T1Z SCRFLX-24-1700T1Z SCRFLX-36-475T1Z SCRFLX-36-600T1Z SCRFLX-36-750T1Z 480 380 415 TYPE LBS KGS 28 40 24 35 12 15 19 25 17.5 25 C 380 163 37 50 32 45 16 20 26 35 C.F. endstream endobj 279 0 obj <> endobj 280 0 obj <>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageC]/XObject<>>>/Rotate 0/TrimBox[0 0 612 792]/Type/Page>> endobj 281 0 obj <>stream PAGE 3. 10. After electrical connection is completed, the charger is ready for operation. 9.2 Momentary Remote and Stop Operation . 2.0 INTRODUCTION The GNB SCRFLX battery chargers are convection cooled, solid state, micro-processor controlled SCR regulated chargers designed to make battery charging simple. i)Do not operate this unit if it has received a sharp blow, been dropped or otherwise damaged. The DC charging cable has a commonly used battery plug or receptacle. h)This charger is factory set to charge lead-acid batteries only. The charger comes with a fuseblock rated big enough to accommodate the highest possible current and voltage for that particular model. Take it to a qualified GNB service center. SCRFLX SERIES INDUSTRIAL BATTERY CHARGERS 1.0 IMPORTANT OPERATING AND SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS a) Before using the battery charger, read all the instructions in addition to the CAUTION, WARNING, and DANGER markings on the charger, battery and all the associated equipment. If pressed a second time, it will cancel the equalize charge mode. Technical specifications Exide 12/5.5 TEMPERATURECOMPENSATING INCLUDED Click here for more information. 1. If the voltage is not under voltage, please open the charger casing in case of power failure, and observe whether the fuse, transformer, circuit board and other components are obviously burnt or damaged. Keep in mind if the charger is set for more than 100% of Ah of the charger rating the charging time will increase proportionately (up to 16 hours). more great content like this. The BLACK DC cable must be connected to the battery negative (-), and the RED DC cable must be connected to the battery positive (+). 7.2 OPTIONS. Battery chargers restore the electrical energy used during battery operation back to a full state of charge. In order to permit free air flow for convection cooling allow four inches minimum between the charger and any wall, six inches from other equipment, and never store anything beneath and on top of the charger. Home Delivery World USA 2023 - only two months left! Verify connection of primary windings of power transformer and AC fuses of charger per connected AC voltage and electricians tag. PAGE 1. Battery chargers come in many shapes and sizes designed to replace the energy consumed with the highest level of efficiency. Australia, FMH, In no event shall the original user be entitled to recover for contingent expenses resulting from but not limited to, telephone calls, telegrams, travel expenses, lodging, duties and taxes, labor, rental or replacement equipment, loss of business or profits or other commercial losses. In the "ON" position, AC power is supplied to the charger but the door cannot be opened. This warranty is extended by GNB only to the original user who purchases or leases a new charger product from GNB or one of its authorized representatives. Battery chargers restore the electrical energy used during battery operation back to a full state of charge. The GNB SCR100 battery chargers are convection cooled, solid state, micro-processor controlled SCR regulated chargers designed to make battery charging simple. GNB shall not be obligated to reimburse the original user or any other person for any work performed. In order to deliver the best experience please tell us where you are located. The floor mounting must be done with #3/8-16 UNC bolts (steel rack) or #3/8 lag screws and anchors (concrete floor). Incorrect. Consult GNB technician. Proper installation is important in order to achieve good charger performance and long troublefree operation and to prevent damage to the charger and batteries. 9.1.2 9.1 SCRFLX CHARGER FUNCTIONAL DESCRIPTION CHARGING 9.1.2.1 CHARGING LED This section gives a brief description of each LED, pushbutton, and the delay function on the SCRFLX type charger front control panel. Enter your email address and check your inbox. NOTE: The following applies to three phase chargers only: if the charger indicates FAC or F3 upon startup, it means that there is a low or high AC voltage (+35%) or AC phase missing. The charger will automatically charge a battery per the Ah rating set at the factory. "A%i_ 4]Y8xA)DPFc(9a@)JJI}Hxvxq%Qh1WZ"&8;$skmZe'h7+|FF3_pMpA&(%:t0l=w]; 3.3 Chargers DC fuse blown. For proper connection, torque the screws to approximately 25 inch-pounds. The equipment has been f actory set and does, This product has been designed, manufactured and certified to be, in conformance with UL Standards. The rating is suitable for the intended input supply and ' lead, The connector polarity is correct and matches the polarity of, A hand operated lockable isolator should be used in the, installation, to enable the charger to be disconnected from the, supply, for maintenance or repair work. Or no voltage output, you can determine that the rectifier module is faulty. any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and "."). they are displayed when no battery is connected. Proper fuse ratings can be found in Table 2 and Table 3(see pages 9-12) for AC input fuses (F1, F2 in case of a single phase input or F1, F2, F3 in case of a three phase input). It can be inferred that the charger fault is caused by the control board. - C.F. Refer to Appendix A (on page 19) for a complete list of codes. Except as authorized in writing, this warranty does not cover any equipment that has been repaired or modified by any party other than GNB. Testing has ensured that the, battery and c harger combination conform as a system for use in, Light and Heavy Industrial environments for each respective, product variant. The end user will have to install two separate push buttons to the appropriate terminals on the Remote Stop / Equalize circuit board (see schematic 4120-66-68650-50) and locate them to a. convenient location for use. The generator should have, load step immunity to prevent undershoot and overshoot with, typical loads. Regulation The finish rate is 4.5 amps for each 100 amp-hour size of the charger rating at 2.6 VPC (+/-1% with a line variation of +6/-10%). United States, Peak Technologies, The charger has a comprehensive self-checking diagnostic program to control all charger functions, monitor the quality of charge and check its own safety conditions. thx welder libor Posted 22 May 2020 14:53 Discussion started by Libor_Tobolak California, United States libor tobolam Post a Reply Report this post Having trouble using the Discussion Forums? Large easy to read LEDs, three button keypad and LED display report on charger and battery status. Exide Battery Charger Product Support | ManualsOnline.com Having trouble using the Discussion Forums? The charger comes with a ground lug attached to the stud, clearly marked on the chassis. 2. 4.2 Battery with wrong number of cells connected to a charger. SHOW MORE . During the last six (6) years of the ten (10) year warranty on power transformers, SCR's and silicon diodes, GNB will bear costs of parts replacement only; no labor or other services will be provided by GNB. NOTE: Only HRCI-R type fuses (ECSR or equivalent) with the notched ferrule at one end can be used. It is a requirement to ground the chassis while the charger is connected to AC power. d)If the battery is unplugged during charging, the charger will indicate OFF/FCA. European Parliament last week passed the new EU Machinery Regulation. IF THIS IS NOT AVAILABLE, A FLOOR PLATE OF AT LEAST 1.43mm GALVANIZED OR 1.6mm UNCOATED STEEL EXTENDED AT LEAST 150mm BEYOND THE EQUIPMENT ON ALL SIDES MUST BE INSTALLED. 13.0 SCRFLX TROUBLESHOOTING 1.Symptom => NO DISPLAY INDICATION AFTER CONNECTION OF AC POWER Possible Cause Action Charger connected to low AC voltage. 1. Login to open Once finished, refer to Table 2 (pages 9-10) for the correct size of AC input fuses. The SCR100 chargers are delivered on skids for easy handling using a fork lift truck. PACIFIC CHLORIDE GNB Industrial Power Motive Power GNB Industrial Power Motive Power Exide Technologies Chloride Motive Power 829 Parkview Boulevard Lombard, IL 60148-3249 U.S.A. Tel: 877.GNB.INFO Fax: 630.691.7869 8301 Keele Street Maple . 299 0 obj <>/Filter/FlateDecode/ID[<4334B8E94645554495867010547383D1>]/Index[278 41]/Info 277 0 R/Length 100/Prev 768261/Root 279 0 R/Size 319/Type/XRef/W[1 2 1]>>stream Verify AC voltage per nameplate of the charger and electricians tag. DELAY CIRCUIT CAUTION: HAZARDOUS VOLTAGES INSIDE. GNB 2100LP OPERATING INSTRUCTIONS MANUAL Pdf Download 3.2Primary switch contacts, fuses, bulbs, and filters are not warranted unless found to be defective prior to use. The charger is warranted for four (4) years from the date of manufacture as determined by the product serial number, with the following exceptions: 3.1Power transformers, SCR's and silicon diodes are warranted for ten (10) years from the date of manufacture of the charger(s) of which they are a part. During the initial three (3) years of charger warranty period, GNB will bear all parts and labor costs of such repair or replacement. WARNING: IMPROPER WIRE AND JUMPER CONNECTION MAY CAUSE SEVERE DAMAGE TO THE CHARGER AND BATTERY, 120 VAC CONFIGURATION (120/208/240V INPUT), 208 VAC CONFIGURATION (208/240/480V INPUT), 208 VAC CONFIGURATION (120/208/240V INPUT), 240 VAC CONFIGURATION (208/240/480V INPUT), 240 VAC CONFIGURATION (120/208/240V INPUT), 480 VAC CONFIGURATION (208/240/480V INPUT), 208VAC CONFIGURATION (208/240/480V INPUT), 240VAC CONFIGURATION (208/240/480V INPUT), 480VAC CONFIGURATION (208/240/480V INPUT), 208VAC CONFIGURATION (208/240/480V INPUT) (SCR100-XX-YYYT1Z ONLY), 240VAC CONFIGURATION (208/240/480V INPUT) (SCR100-XX-YYYT1Z ONLY), 480VAC CONFIGURATION (208/240/480V INPUT) (SCR100-XX-YYYT1Z ONLY). Before using the battery charger, read all the instructions in addition to the CAUTION, WARNING, and DANGER markings on the charger, battery and all the associated equipment. PAGE 2. 8.2.3 AMPHR Release the UP or DOWN button to display the cumulative amp-hours returned to the battery as: [xxxx H]. Exide Battery Charger tn80dx080 1 Solutions there is no problem just want to go over setup 6a Exide Battery Charger 7001207 0 Solutions Is a wiring diagram available for Exide NPC 18-3-9 Exide Battery Charger NPC 18-3-950L 0 Solutions need manual for exide model ES3-12-850 charger Exide Battery Charger ES3-12-850 0 Solutions Electric stacker battery charging considerations. f)De-energize all AC and DC power connections before servicing this unit. The charger is used within the published performance rating for the unit involved. Exide Technologies SCRFLX User Manual To permit free air flow for convection cooling allow four inches minimum between the charger and any wall, six inches from other equipment, and never store anything beneath or on top of the charger. Contact us for help. What are the commonly used batteries for AGV cars? In no event shall the original user be entitled to recover for contingent expenses resulting from but not limited to, telephone calls, telegrams, travel expenses, lodging, duties and taxes, labor, rental or replacement equipment, loss of business or profits or other commercial losses. 318 0 obj <>stream Step 4: Check the battery charging current SALES - SERVICE - RECYCLING SCR200 SERIES INDUSTRIAL BATTERY CHARGERS 1-888-563-6300 in the USA INSTALLATION & OPERATING INSTRUCTIONS 1-800-268-2698 in Canada SALES - SERVICE - RECYCLING TOLL FREE 1-888-563-6300 in the USA 1-800-268-2698 in Canada V19CIL5200ULS 2006-11 GNB Industrial Power A Division of Exide Technologies For the first Keep the manual in a s afe and c onvenient, It is advisable to thoroughly read the information on battery safety. THE CHARGER PROPERLY USING THE THREADED M6 HOLE (GND) PROVIDED. Continue the AC wiring to fuseholder terminals L1 (N) and L2 (L) (single phase input) or L1, L2, and L3 (three phase input), ensuring that the AC source phases match the phase rotation on the AC input. When stacking chargers on top of each other, ensure that cabinets are bolted together using properly sized black #1/4-20 UNC hardware provided in all four corners on top cover.
Who Is Dwight Married To In Real Life, Biltmore Estate Donation Request, Remote Paid Tech Apprenticeship, Articles E
exide charger fault codes 2023